Welcome to the company ! we have many years of professional experience !
rsdgj@pyzyrsd.com +86 513525609655

Composition analysis of fracturing flowback fluid

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

Composition analysis of fracturing flowback fluid
Acid Waste Neutralization - AQUAMAG®
Acid Waste Neutralization - AQUAMAG®

AQUAMAG, ® and, MAGOX, ® are two of the most effective reagents available for the neutralization of acid waste streams such as hydrochloric acid (HCl) and …

Characterization and Treatment of Real Wastewater from an ...
Characterization and Treatment of Real Wastewater from an ...

23/5/2019, · The rejection of the stage of ,electroplating, deposit contains widely metals and the following anions: BO 3−, CO 2− 3, Cr 2 O 2− 7, F −, PO 4 3−, Cl −, NO −3 and SO 4 2−. Generally, ,wastewater, contains many heavy metals. The most important of cations are Cr 6+, it is reduced to Cr 3+, while CN-is oxidized in the preliminary ...

Electrochemical oxidation of polyethylene glycol in ...
Electrochemical oxidation of polyethylene glycol in ...

Electrochemical oxidation of polyethylene glycol (PEG) in an ,acidic, (pH 0.18 to 0.42) and high ionic strength ,electroplating, solution was investigated. The ,electroplating, solution is a major source of ,wastewater, in the printing wiring board industry.

Study of the electrocoagulation of electroplating industry ...
Study of the electrocoagulation of electroplating industry ...

acidic, medium, the predominance of the free cation Al 3+ is observed until pH 3.5. As the pH increases, different ... The EC experiments were performed on the settled ,wastewater, of ,electroplating, industry with two aluminum electrodes fitted in a volume of 1.8 liters. The electrodes have the following dimensions: length = 15 cm, width

Selected Heavy Metals Removal From Electroplating ...
Selected Heavy Metals Removal From Electroplating ...

14/3/2019, · In addition, ,electroplating wastewater, is highly coloured, turbid, too ,acidic, (low pH), and can cause bio-distortion when leached into plant via soil, which indirectly causes toxins in foods and ...

Wastewater Neutralization Systems - pH adjustment
Wastewater Neutralization Systems - pH adjustment

Battery, Acid Neutralization, Systems for the pH, neutralization, of concentrated acids such as battery acid or, sulfuric acid., These systems are designed to handle the heat and energy released during the, neutralization, of concentrated, acids, by controlling the rate of reaction and through the use of process cooling. To Learn More Click Here..

Sulfuric Acid for use in pH Neutralization Systems
Sulfuric Acid for use in pH Neutralization Systems

One mole of sulfuric acid will neutralize two moles of sodium hydroxide, as follows: 2NaOH + H 2 SO, 4 → Na, 2 (SO), 4 + 2H 2 0 . As with any concentrated acid extreme caution must be exercised when working in the area of sulfuric acid. Sulfuric acid will quickly decompose organic material including human flesh. Additionally the neutralization of sulfuric acid or pH neutralization reactions involving sulfuric will …

Improving the Electroplating Process Using pH Control ...
Improving the Electroplating Process Using pH Control ...

13/6/2017, · ,Electroplating Wastewater, Treatment. ,Electroplating wastewater, must be treated for toxic chemical removal before discharge to municipal sewers. Just as pH needs to be controlled in the ,electroplating, process to keep metal ions in solution, pH can also be used in ,wastewater, treatment to precipitate ions for removal via sedimentation and filtration.

Sulfuric Acid for use in Industrial pH Neutralization Systems
Sulfuric Acid for use in Industrial pH Neutralization Systems

Sulfuric acid is used almost universally for, neutralization reactions., It is easier and safer to use than HCl or HNO3and is more potent than all of the other acids except for phosphoric. Although adverse reactions are always a possibility, they are rare. If calcium is present then calcium sulfate (CaSO4), also known as gypsum, will precipitate.

BIOSORPTION OF Cr(VI) FROM SYNTHETIC WASTEWATER …
BIOSORPTION OF Cr(VI) FROM SYNTHETIC WASTEWATER …

the ,wastewater, are shown in Table 1. Table 1. Physicochemical Characteristics of ,Electroplating, Rinse ,Wastewater, Contents in mg/L Cr (VI) Ni2+ Ca2+ Mg2+ Cl-SO 4 2-Na+ K+ TDS pH Conductivity (µS/cm) 7.70 177.6 126.2 56.1 159.726.78 63.8 3.14 790 7.19 1670 Batch Biosorption Experiments

Chemicals used for pH Neutralization of Industrial Wastewater
Chemicals used for pH Neutralization of Industrial Wastewater

Chemicals Used for pH Adjustment of Industrial Wastewater. The most commonly used neutralization chemicals for acid or base neutralization are, 93% Sul,furic acid and 50% Sodium hydroxide. In many cases these are very good choices, however, there are many considerations when selecting chemicals and these may not always be the best selection.

KR100847444B1 - Method for neutralizing sulphuric acid ...
KR100847444B1 - Method for neutralizing sulphuric acid ...

A method for, neutralizing sulfuric acid wastewater, by using, calcined dolomite, is provided to reduce the total cost by substantially reducing the injection quantity of, calcined dolomite, required for...

14 Industrial Wastewater Treatment Principals and Ideas
14 Industrial Wastewater Treatment Principals and Ideas

12. What are the characteristics and treatment principles of acid-base ,wastewater,? ,Acidic wastewater, mainly comes from steel plants, chemical plants, dye factories, ,electroplating, plants and mines, which contain various harmful substances or heavy metal salts. The acid mass fraction varies widely, from less than 1% at low and greater than 10% ...

Neutralization - ScienceDirect
Neutralization - ScienceDirect

1/1/2007, · ,Na2SO4 + 2H2O wastewater sulfuric acid, as neutralizer resulting neutral salt A titration curve of the alkaline waste neutralized with various amounts of H2SO4 is helpful to ascertain the quantities of acid required for neutralization to definite pH values and the relevant costs.

REMEDIATION OF HEAVY METAL BEARING WASTEWATER BY ...
REMEDIATION OF HEAVY METAL BEARING WASTEWATER BY ...

The actual ,wastewater, was obtained from an ,electroplating, unit located near Thessaloniki, northern Greece, with the main characteristics listed in Table 1. Table 1. Main characteristics of ,electroplating wastewater, . Parameter: Value: pH 4.5 Conductivity 4500 μS/cm (after addition of KCl) Cr (VI) mg/L 86 Ni (II) mg/L 65 Cu (II) mg/L 37

REMEDIATION OF HEAVY METAL BEARING WASTEWATER BY ...
REMEDIATION OF HEAVY METAL BEARING WASTEWATER BY ...

The actual ,wastewater, was obtained from an ,electroplating, unit located near Thessaloniki, northern Greece, with the main characteristics listed in Table 1. Table 1. Main characteristics of ,electroplating wastewater, . Parameter: Value: pH 4.5 Conductivity 4500 μS/cm (after addition of KCl) Cr (VI) mg/L 86 Ni (II) mg/L 65 Cu (II) mg/L 37

Sulfuric Acid for Wastewater Treatment | Beckart
Sulfuric Acid for Wastewater Treatment | Beckart

Sulfuric Acid. Sulfuric acid is the acid of choice for many, pH neutralization, applications due to its high effectiveness and strong acidic nature. Typical Applications: Industrial and sanitary wastewater. pH neutralization. Emulsion breaker. Typical Properties:

Treatment of Electroplating Waste -- Student Project
Treatment of Electroplating Waste -- Student Project

2000. A. Anusha: Some good books available on the ,treatment of electroplating waste, include: "Operation and Maintenance of Surface ,Finishing Wastewater, Treatment Systems" [affil. link to book on Amazon] and Water and Waste Control For the Plating Shop".For a much briefer treatment of the subject, there is coverage in the Metal ,Finishing, Guidebook, the "Products ,Finishing," Directory, and the ...

Electroplating- Lenntech
Electroplating- Lenntech

Wastewater, composition: Almost all the substances and products used in ,electroplating, can be found in the ,wastewater,, for instance ,acidic, solutions, toxic metals, solvents, and cyanides. This contamination is a consequence of the different process steps such as spillage, rinsing, dumping of process baths.

Chat Online Inquiry Email

Business cooperation

+86 513525609655

Company address

Road West, North Branch, Jingkai Road, Puyang City