Welcome to the company ! we have many years of professional experience !
rsdgj@pyzyrsd.com +86 513525609655

Treatment of acidic wastewater

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

Treatment of acidic wastewater
Industrial wastewater treatment - Wikipedia
Industrial wastewater treatment - Wikipedia

Industrial wastewater treatment, describes the processes used for treating ,wastewater, that is produced by industries as an undesirable by-product. After treatment, the treated industrial ,wastewater, (or effluent) may be reused or released to a sanitary sewer or to a surface water in the environment.. Most industries produce some ,wastewater,.Recent trends have been to minimize such production or ...

INDUSTRIAL CRYSTALLIZATION AND PRECIPITATION FROM ...
INDUSTRIAL CRYSTALLIZATION AND PRECIPITATION FROM ...

For growth controlled by diffusion (e.g., some cases of ,crystallization, of compounds with a high solubility, static ,crystallization, and ,crystallization, from viscous solutions) the growth rate becomes The mass transfer coefficient, k d = D/ d, can be derived from several correlations for the Sherwood number, Sh = k d L/D, such as Sh = 2 + 0.6 Re 1/2 Sc 1/3 .

pH Adjustment Calculation : Wastewater
pH Adjustment Calculation : Wastewater

I have ,wastewater, with a ,pH, value of 10 (i.e flow rate = 100 m3/h). This value need to be reduced to 7. How can I ,calculate, the chemical flow rate needed (i.e HCl 32%) to reduce ,the pH, from 9 to 7? I can't do a trial and error experiment because the ,wastewater, is not available yet.. Thanks!

pH Adjustment Systems | PRAB
pH Adjustment Systems | PRAB

We offer a Continuous ,pH, Adjusting System for higher flow rates (> 10 gpm) and batch ,pH, Adjusting System for a lower flow rate (typically less than 10 gpm). Before discharging the effluent from a ,wastewater, treatment system to a publicly owned treatment works (or sewer) there is a specific ,pH, range that must needs to be met for compliance as ,pH, is constantly monitored.

100+ documents about crystallization process - 1Library
100+ documents about crystallization process - 1Library

Phosphorus ,removal, and recovery from high phosphorus ,wastewater, by the HAP ,crystallization, process In the experiment, the ,crystallization, process was compared with the chemical precipitate process for phosphorus ,removal, efficiency. Calcites were used as seeds to remove and recover phosphorus from synthetic phosphorite ,wastewater,.

How to calculate the amount of citric acid to neutralise ...
How to calculate the amount of citric acid to neutralise ...

When ,the pH, reaches 10.5 we add citric ,acid, to bring ,the pH, down. How many liters of citric ,acid, with a ,pH, of 2.2 should we add to the system to bring ,the pH, down to around 7. We always end up putting too much in then add caustic to bring it back up.

The Basics of Mining Wastewater Treatment | ChemREADY
The Basics of Mining Wastewater Treatment | ChemREADY

For total solids ,removal,, you will need to employ another means of ,wastewater, treatment as well, like a high-efficiency filter press. However, hydrocyclones will allow you to remove a significant number of solids and aggregate prior to your primary method of ,wastewater, treatment, offering an …

Crystallization Design: It's Crystal Clear
Crystallization Design: It's Crystal Clear

23/10/2003, · Indirect ,cooling crystallization, requires slow ,cooling, of the batch after seeding, followed by an accelerated temperature drop vs. time. The coolant should also have a programmed drop in temperature over time. Low log mean temperature differences (LMTDs), often as low as 1-5 Degrees F, are required to stay within the metastable zone.

Frontiers | Two-Stage Crystallization Combining Direct ...
Frontiers | Two-Stage Crystallization Combining Direct ...

Owing to the problems of low concentration and difficulty in recovering the remaining succinic ,acid, from the fermentation broth after ,cooling crystallization,, if concentrated, solvent extraction and ion exchange chromatography are used, high amounts of energy are consumed, and a great deal of ,wastewater, …

Greenhouse & Floriculture: Adjusting Alkalinity with Acids ...
Greenhouse & Floriculture: Adjusting Alkalinity with Acids ...

AlkCalc - This calculator provides the recommendations for the amount ,of acid, to add to irrigation water in order to modify ,the pH, and alkalinity levels. It also provides the amount of added phosphorus, nitrogen, and sulfur that the corresponding acids will provide, plus an economic comparison of each ,acid,.

How can we adjust the pH of wastewater intended for ...
How can we adjust the pH of wastewater intended for ...

You have to adjust Ph by, Ca (OH)2, and, addition alkalinity of the wastewater.

What acid to use for adjusting wastewater pH?
What acid to use for adjusting wastewater pH?

1) How do I know which ,acid, dissociation constant pKa to use 2.16 or 7.2 or 12.32 (7.2 because it's closest to my target ,pH,?) 2) Next how to I use the HH equation ,pH, = pKa + log ([H2PO4-]/[H3PO4]) ?

RECOVERY OF p-TBC FROM A BUTADIENE WASHING STREAM IN …
RECOVERY OF p-TBC FROM A BUTADIENE WASHING STREAM IN …

avoid ,crystallization, of salts after ,cooling,. Results indicated a COD ,removal, of 97% and a p-TBC recovery of 88 g L–1 of washing stream. Since Petroflex generates approximately 15,000 L of that stream per month, that would mean a monthly recovery of 1,320 kg of p-TBC. Therefore, a significant reduction in the amount of organic matter

Wastewater treatment and recycle from a semiconductor ...
Wastewater treatment and recycle from a semiconductor ...

Before reusing treated water as ,cooling, tower make-up water, a final pH adjustment was carried out to minimize ,cooling, tower corrosion. Sulfuric ,acid, was dosed into the RO permeate to reduce the pH to the target of 6.5–8.0 (results are not shown). All parameters had achieved the targeted standards.

pH Adjustment - Newfoundland and Labrador
pH Adjustment - Newfoundland and Labrador

Pure Water pH=7 Toothpaste pH=9 Lemon Juice pH=2., pH, Scale., • Each whole value below 7 is 10 times more acidic than the previous number • For example, pH 3 is 10 times more acidic than pH 4 andis 100 times more acidic than pH 5 • For every number decrease we have to multiply by 10 • …

How do I Calculate the Amount of Acid to Reduce Water pH ...
How do I Calculate the Amount of Acid to Reduce Water pH ...

Calculate how much acid you need to obtain the pH level of your target value. Work this out using the following formula:, M_1V_1 + M_2V_2 = M_3 (V_1 + V_2), In this equation,, “M_1” is, the molarity, of the, acid,, “V_1” is the, volume, of the acidic solution,,, “M_2” is, the molarity of the water and, “V_2” is, the, volume of the water.

Chemical treatment technologies for waste-water recycling ...
Chemical treatment technologies for waste-water recycling ...

Generally, ,crystallization, is used for the ,wastewater, released ,by cooling, towers, coal and gas fired boilers, and the paper and dying industries. It is also used for source reduction. Forced circulation, draft tube baffle, surface cooled crystallizers and fluidized suspensions are used for ,crystallization,.

Preparation of ZnSO 4 ·7H 2 O using filter cake enriched ...
Preparation of ZnSO 4 ·7H 2 O using filter cake enriched ...

The ZnSO 4 ∙7H 2 O is prepared from smithsonite (ZnCO 3) by a process involving roasting, leaching, impurity ,removal,, evaporating, ,cooling,, and ,crystallization,.

pH Adjustment and Neutralization the basics
pH Adjustment and Neutralization the basics

The task of any pH adjustment system is to adjust the pH of the process stream into the defined acceptable discharge range. In the case of an acid neutralization, caustic (NaOH) is added to the effluent stream to pH Neutralize the solution. This neutralization, or titration can be expressed as follows:, HCl + NaOH, →, NaCl + H 2, O

Chat Online Inquiry Email

Business cooperation

+86 513525609655

Company address

Road West, North Branch, Jingkai Road, Puyang City